Choosing a DC fast charger is a specification exercise, not a wattage contest. Site, vehicles, charging positions and available electrical capacity decide the rating, not the largest number in a catalogue. Wattecho publishes DC equipment across a 60–480 kW range on its DC EV charger category page. This is the sequence our team runs with CPOs, EPCs and procurement teams: define the project, shortlist from published power options, then verify configuration, electrical data, cooling, connectors, network and documentation on the model page itself.

Wattecho pages state their own application scope. The integrated DC charging pile page lists urban dedicated and public stations for fleets, buses and taxis, parking lots in residential districts and shopping plazas, and intercity highway stations, including rapid deployment on constrained sites. The WELCND-480E 480 kW station page lists expressway service areas, urban core business districts, large parking lots, public transit and logistics depots and industrial parks. The national standard high-power system and silicon carbide system pages describe heavy-duty work such as mining sites, construction machinery, electric trucks and electric tanker trucks.
These are stated scopes, not proof that a given rating fits your duty cycle.
Write these down first:
This is the buyer’s input list, not a statement of what any model provides. Shortlist only after these requirements are recorded.
| Wattecho product series | Power options listed on the page | Configuration details listed | Product page |
| Electric Vehicle DC Integrated Charging Pile | 60, 80, 120, 160, 180, 240 kW | Floor-standing, AF-DC-60 to AF-DC-240, air cooling, IP54 | Page |
| Electric Vehicle DC Wall-Mounted Charging Pile2 | 60 kW | Wall or column mounted, air cooling, IP54 | Page |
| DC Fast Charging Station with One Unit & Four Guns | 160, 200, 240, 320 kW | 4 guns, 2- or 4-gun simultaneous charging, matrix power adjustment, IP54 | Page |
| National Standard DC Pile Charging System | 60, 80, 120, 160 kW | Passenger and bus versions, 200~750 V output, IP54, air cooled | Page |
| National Standard High-Power Charging System | 180, 240, 320, 360, 400 kW | Heavy-duty truck use, two fast guns, full power per gun or dual simultaneous, IP54 | Page |
| Silicon Carbide High-Power Charging System | 240, 320 kW | Heavy commercial vehicles, dual fast charging, IP54, air-cooled | Page |
| Electric Vehicle DC Integrated Charging Pile 320–480 kW | 320, 360, 400, 480 kW | Floor-standing, AF-DC-320 to AF-DC-480, air cooling, IP54 | Page |
| DC Split-Type Charging Station 240–480 kW | 240, 320, 360, 400, 480 kW | Cabinet AF-DC-240 to AF-DC-480, 2–8 guns, standard or liquid-cooled terminals | Page |
| Ultra-Fast Charging Station 480 kW | 480 kW | WELCND-480E, 4 guns, 2×HPC + 2×CCS2, forced air cooling, IP54 | Page |
| Liquid-Cooled Flexible Group Charging System | 360, 480 kW | Host plus terminal architecture, liquid cooling, IP55, 4G | Page |
| European Standard DC Pile Charging System 120–180 kW | 120, 160, 180 kW | Dual-gun, air cooling, IP55, CE | Page |
A separate European Standard DC Pile Charging System page lists 150, 240 and 320 kW ratings and notes that some parameters vary by configuration.
Four series publish options here and they are not interchangeable: the integrated and national standard DC piles at 60 to 160 kW, the wall-mounted pile at 60 kW and the four-gun station at 160 kW. The wall unit is 600×700×320 mm on a wall or column; the integrated pile is floor-standing at 1700×820×620 mm.
At 240 kW, compare the integrated AF-DC-240-Y-B-O-4-H, the silicon carbide system, the split-type cabinet AF-DC-240, the national standard high-power WE-Z-240KW-ZK and the European standard page. Cabinet dimensions alone run from 780×620×1800 mm to 1750×1200×900 mm.
The 320 kW rating appears across six series. The 360 and 400 kW ratings appear on the integrated 320–480 kW page, the split-type cabinet and the national standard high-power system.
Four 480 kW options sit in four architectures: integrated AF-DC-480-Y-B-O-4-H, split-type cabinet AF-DC-480 feeding separate terminals, the WELCND-480E with 2×HPC + 2×CCS2, and the 480 kW rating on the liquid-cooled group system.

Power conversion and the charging point share one enclosure. The 60–240 kW page covers six models at 1700×820×620 mm and the 320–480 kW page four at 1850×1000×900 mm. Both are floor-standing, air cooled and IP54, with separate current fields.
The four-gun station is one unit with four guns at 160, 200, 240 and 320 kW. The page lists 2- or 4-gun simultaneous charging, matrix power adjustment, a 1720×850×650 mm cabinet, IP54, −25 °C to +55 °C and two 5 m plus two 7.5 m cables. No division table is published for each combination of active guns.
On the 240–480 kW split-type page, the main cabinet carries 240 to 480 kW with 2–8 guns, measures 1750×1200×900 mm, and is air cooled and IP54. The terminal table is separate: AF-DC-250A-A/B-O-4, standard terminal, 5–250 A per gun; AF-DC-500A-A/B-O-4, liquid-cooled terminal, 5–500 A per gun. Liquid cooling here is a terminal option, not the whole station.
The liquid-cooled group system uses a host plus terminal architecture. Within this range the page lists 360 kW and 480 kW options under model WEZST720-720N1, with liquid cooling, IP55, 4G, 940×1350×1950 mm, 380 V AC ±15% three-phase five-wire input, DC 200–1000 V output and −35 °C to +50 °C. Gun quantity for the series must be confirmed with Wattecho rather than read from the page.
Gun count drives access, traffic flow and energy distribution, so treat it as an operating decision rather than a checkbox. Four pages make explicit statements. The four-gun station lists 4 guns, 2- or 4-gun simultaneous charging and matrix power adjustment. The national standard high-power system lists two fast guns with full power per gun or dual-gun simultaneous charging. The WELCND-480E lists 4 guns, intelligent power distribution and an external dispenser connection for four vehicles. The split-type page states 2–8 guns plus single and dual-gun terminals.
Three rules follow. Cabinet rated power and power at each gun are different fields; a 240 kW four-position cabinet implies no figure per position. A total output current range is not a per-gun schedule. Where allocation logic is unpublished, put it in the inquiry: full output to one vehicle, an even split, or a schedule set from the platform. On the national standard DC pile page, the single-gun full power and dual-gun equal sharing row sits next to a differently labelled field, so confirm its meaning.
Most series list AC 380 V ±15%, including the integrated pages, the four-gun station, the national standard and silicon carbide systems and the European standard 120–180 kW page. The European standard DC pile page lists 400 V ±15%, and the WELCND-480E lists AC 400 V ±15% with a rated AC current of 736 A (368 A ×2). Frequency ranges from 45–60 Hz to 50/60 Hz, and the liquid-cooled group system lists 380 V AC ±15% at 45–66 Hz. Treat input voltage as model specific.
Output voltage is 200–1000 VDC, with a 300–1000 VDC constant-power window, on the Integrated, Split-Type, Wall-Mounted and National Standard High-Power Charging System pages. The WELCND-480E lists 150–1000 VDC. The National Standard DC Pile Charging System lists 200–750 VDC, with 1000 VDC optional on the 80, 120 and 160 kW ratings. The Silicon Carbide High-Power Charging System page lists both 200–750 VDC and 200–1000 VDC without stating which range applies to each rating.
Rated current and output current are separate rows and must not be merged. The integrated 60–240 kW page lists rated current from 0–96 A to 0–384 A across six models, but its output current row carries only two values, 0–200 A and 0–250 A; the 320–480 kW page lists rated current from 0–512 A to 0–768 A against an output current row of 0–300 A. Do not use those rows to rank models or derive a per-gun figure. Where model-level figures are published, quote them as listed: the four-gun station gives an output current range per rating, the national standard high-power system a maximum single-gun current, and the WELCND-480E HPC 600 A (800 A for 2 minutes) and CCS2 400 A (500 A for 10 minutes).
Efficiency is a page-level statement with different wording: ≥95% on the integrated, split-type and wall-mounted pages, and 95% or ≥95% on the European standard 120–180 kW, national standard high-power and WELCND-480E pages. The category page introduction makes a general claim for the range, which is not a model specification. Where pages publish it, power factor is listed as ≥0.99 above 50% load.
Air Cooling is listed on the integrated pages, the split-type main cabinet and standard terminal, the wall-mounted unit, and the national standard and silicon carbide systems. Forced air cooling is listed on the WELCND-480E. Liquid cooling is listed on the liquid-cooled group system, and on the split-type page it applies to the AF-DC-500A terminal only. The four-gun station page does not state a cooling method. The category page’s liquid-cooled description covers part of the range; it does not make an air-cooled model liquid cooled. Where a page is silent, ask in the inquiry.
Installation is floor-standing except for the 60 kW wall unit, which mounts on a wall or column. IP54 covers most of the range, including the WELCND-480E, which adds IK10 and an IK08 screen; IP55 covers the European standard and liquid-cooled group pages. Operating temperature is −20 °C to +50 °C on the integrated and split-type pages, −25 °C to +55 °C on the four-gun, national standard and silicon carbide pages, −30 °C to +55 °C on the European DC pile page and −35 °C to +50 °C on the liquid-cooled group system. The WELCND-480E lists −25 °C to +50 °C with derating to 65 °C and a 2000 m altitude limit with derating to 4000 m.
Connector information is unevenly published. The WELCND-480E page is explicit: 2×HPC + 2×CCS2. The European standard pages describe compatibility with European-standard electric vehicles, which indicates a market standard rather than a connector code list. The remaining pages give output voltage, cable length and gun count but no connector combination, so confirm it in the inquiry.
The category page introduction states OCPP 1.6J/2.0.1 integration, and a later block on the same page is headed OCPP 1.6J Compatibility, both at category level.
Two product pages state a version themselves. The European standard 120–180 kW page lists OCPP 1.6 compatible with CE certification and DIN 70122 support. The European standard DC pile page lists OCPP 1.6 and DIN 70122. The WELCND-480E lists OCPP 1.6J with ISO 15118 and DIN 70121.
The integrated piles, the four-gun station, the split-type station and terminals, the wall-mounted unit, the national standard and silicon carbide systems list Ethernet and 4G and state no OCPP version. The liquid-cooled group system lists 4G; the WELCND-480E adds Wi-Fi. Transport is not a protocol version, so state your required version in the inquiry.
Standards statements belong to specific pages. The integrated, split-type and wall-mounted pages list EN IEC 61851-1, EN 61851-23, EN IEC 61851-21-2 and EN IEC 61000-6-1; the 320–480 kW and split-type pages add IEC 62196-3 compliance and design per IEC 61851-1. The four-gun station lists GB/T 18487.1-2023. The national standard pages describe a national standard design without a number. The European standard pages list CE certification and DIN 70122. The WELCND-480E lists CE, UKCA, RED, ROHS and REACH, noting availability from November 2025. The silicon carbide and liquid-cooled group pages list neither standards nor certificates.
None of this is a market-access conclusion. Certificate scope, revision and destination marks are separate questions, and the authority having jurisdiction reviews the installation. Ask for a declaration of conformity scoped to the exact model.
| Project requirement to check | Wattecho product page to review | What the buyer must confirm |
| 60–240 kW integrated equipment | Integrated charging pile | Rating and model, output data, footprint, cooling |
| 320–480 kW integrated equipment | Integrated pile 320–480 kW | Model parameters, meaning of the published current rows |
| Several vehicles on one unit | Four-gun station | Gun count, simultaneous charging conditions, allocation rules |
| Cabinet separated from dispensers | Split-type station | Cabinet and terminal configuration, terminal cooling, layout |
| 480 kW high-power equipment | WELCND-480E and other 480 kW pages | Connector set, OCPP version, cooling, certificate scope |
| Liquid-cooled group charging | Liquid-cooled group system | 360 or 480 kW option, terminal count, gun configuration |
The most suitable option depends on the project requirements and the specifications documented for the selected model. Use the published power range to shortlist, then verify configuration on the relevant product page.

This is a list of project inputs prepared by the buyer. It does not mean every Wattecho product offers every configuration or function listed.
The category page publishes a 60–480 kW range, but each series lists its own: 60 to 240 and 320 to 480 kW integrated, 160 to 320 kW four-gun, 180 to 400 kW national standard high-power, 240 to 480 kW split-type and 360 or 480 kW liquid-cooled. This article indexes 60–480 kW options only.
Compare the specification tables, not the architecture labels. For split-type equipment, separate cabinet fields from terminal fields, then check gun quantity, the terminal cooling option and the cabinet-to-dispenser distance. Neither architecture is universally preferable; differences appear in layout and service access.
No. Air cooling is listed on the integrated piles, the split-type cabinet and the national standard and silicon carbide pages, and the WELCND-480E lists forced air cooling. Liquid cooling appears on the liquid-cooled group system and on the split-type terminal option, where the main cabinet remains air cooled.
No. The OCPP 1.6J/2.0.1 wording sits in the category page introduction. Among product pages, the European standard pages state OCPP 1.6 and the WELCND-480E states OCPP 1.6J, while several list only Ethernet and 4G.
Check the gun count, whether simultaneous charging is described, whether an allocation method is published, and whether total and per-gun current figures are both stated.
Project location and application, target power and shortlisted model, configuration, connector combination, expected active guns, electrical conditions, cooling and installation constraints, network interface and OCPP version, and the documentation to verify.
Planning a DC Fast Charging Project?
Share your project location, target charging power, preferred charger configuration, electrical requirements, connector needs and communication requirements with Wattecho.
Review the relevant product specifications and contact our team to discuss the models and configuration details for your project. Send your project inputs through the Wattecho contact page.
Request Project Information
We value your privacy
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
Customise Consent Preferences
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.