The Split DC Charging pile is suitable for:
Urban dedicated charging stations (for buses, taxis, official vehicles, sanitation vehicles, logistics vehicles, etc.)
Urban public charging stations (for private cars, commuter vehicles, coaches, etc.)
Various parking lots in urban residential districts, shopping plazas, power business premises, etc.
Intercity highway charging stations and other occasions requiring DC fast charging
Functional
Provide electrical isolation between input and output of the charging pile.
Include a device to prevent battery pack from charging the output filter capacitor, avoiding instantaneous large current when connecting to the battery pack.
Ensure withstand voltage, insulation level, and EMC comply with IEC 62196-3.
Design in accordance with IEC 61851-1 (DC charging and off-board conductive charging specifications), referencing typical design practices for EV charging facilities.
| Product Model | AF-DC-240 | AF-DC-320 | AF-DC-360 | AF-DC-400 | AF-DC-480 | |
| Main Cabinet | ||||||
| Detailed Specifications | Rated Power | 240KW | 320KW | 360KW | 400KW | 480KW |
| Charging Equipment | Supported Gun Quantity | 2-8 Guns | ||||
| Installation | Floor-standing | |||||
| Wiring Mode | Bottom Inlet & Bottom Outlet | |||||
| Equipment Dimensions | 1750*1200*900mm | |||||
| Rated Current | 0-384A | 0-512A | 0-576A | 0-640A | 0-768A | |
| Input Voltage | AC380V±15% | |||||
| Input Frequency | 50±1Hz | |||||
| Output Voltage | 200-1000VDC | |||||
| Constant Power Output Voltage | 300-1000VDC | |||||
| Electrical Indicators | Current Limiting Protection Value | ≥110% | ||||
| Voltage Regulation Accuracy | ≤±0.5% | |||||
| Current Regulation Accuracy | ≤±1% | |||||
| Ripple Factor | ≤±0.5% | |||||
| Efficiency | ≥95% | |||||
| Power Factor | ≥0.99 (above 50% load) | |||||
| Total Harmonic Distortion (THD) | ≤5% (above 50% load) | |||||
| Functional Design | Human-Machine Interface | LED Indicator Lights | ||||
| Safety Design | Execution Standards | ENIEC61851-1,EN61851-23;ENIEC61851-21-2, ENIEC61000-6-1 | ||||
| Safety Functions | Charging Gun Temperature Detection, Overvoltage Protection, Undervoltage Protection, Overload Protection, Short Circuit Protection, Grounding Protection, Over-temperature Protection, Low-temperature Protection, Insulation Monitoring Protection, Polarity Reverse Connection Protection, Lightning Protection, Emergency Stop Protection, Leakage Protection | |||||
| Environmental Indicators | Operating Temperature | -20℃~+50℃ | ||||
| Operating Humidity | 5%~95% (no condensation) | |||||
| Operating Altitude | <2000m | |||||
| Protection Level | IP54 | |||||
| Cooling Method | Air Cooling | |||||
| Noise Control | ≤65dB | |||||
| MTBF | 17520 Hours | |||||
| Product Model | AF-DC-250A-A/B-O-4 | AF-DC-500A-A/B-O-4 | ||||
| Standard Terminal | Liquid-Cooled Terminal | |||||
| Detailed Specifications | Supported Gun Quantity | Single/Dual | Single/Dual | |||
| Charging Equipment | Installation | Floor-standing | ||||
| Wiring Mode | Bottom Inlet & Bottom Outlet | |||||
| Single-Gun Equipment Dimensions | 1517*650*300mm | 1630*500*370mm | ||||
| Dual-Gun Equipment Dimensions | 1517*650*300mm | 1630*600*500mm | ||||
| Rated Current | 5-250A | 5-500A | ||||
| Input Voltage | DC200-1000V | |||||
| Input Frequency | 50±1Hz | |||||
| Output Voltage | 200-1000VDC | |||||
| Constant Power Output Voltage | 300-1000VDC | |||||
| Output Current (Per Gun) | 5-250A | 5-500A | ||||
| Cable Length | 5m/7m (Optional) | |||||
| Measurement Accuracy | Class 1.0 | |||||
| Electrical Indicators | Current Limiting Protection Value | ≥110% | ||||
| Voltage Regulation Accuracy | ≤±0.5% | |||||
| Current Regulation Accuracy | ≤±1% | |||||
| Ripple Factor | ≤±0.5% | |||||
| Efficiency | ≥95% | |||||
| Power Factor | ≥0.99 (above 50% load) | |||||
| Total Harmonic Distortion (THD) | ≤5% (above 50% load) | |||||
| Functional Design | Human-Machine Interface | 7-inch high-brightness color touch screen | ||||
| Charging Modes | Auto Full Charge / Fixed Quantity / Fixed Amount / Fixed Time | |||||
| Charging Methods | Card Swiping / QR Code Scanning / Password | |||||
| Payment Methods | Card Payment / QR Code Payment | |||||
| Networking Methods | Ethernet / 4G Communication | |||||
| Safety Design | Execution Standards | ENIEC61851-1,EN61851-23;ENIEC61851-21-2, ENIEC61000-6-1 | ||||
| Safety Functions | Charging Gun Temperature Detection, Overvoltage Protection, Undervoltage Protection, Overload Protection, Short Circuit Protection, Grounding Protection, Over-temperature Protection, Low-temperature Protection, Insulation Monitoring Protection, Polarity Reverse Connection Protection, Lightning Protection, Emergency Stop Protection, Leakage Protection | |||||
| Environmental Indicators | Operating Temperature | -20℃~+50℃ | ||||
| Operating Humidity | 5%~95% (no condensation) | |||||
| Operating Altitude | <2000m | |||||
| Protection Level | IP54 | |||||
| Cooling Method | Air Cooling | Liquid Cooling | ||||
| Noise Control | ≤40dB | ≤50dB | ||||
| MTBF | 17520 Hours | |||||
Product Video
We value your privacy
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
Customise Consent Preferences
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.