1.Zero Export
2. Time-of-use Control
3. Charge Battery from Module and Grid
4.Parallel Output for Single
5.Three-phase Grids
6.Dynamic Tariff Applicable
7.Battery Optimizer
8.Supports Black Start via PV or Grid
| Model | TSOL-MSU4000Lite |
| PV Input (PV) | |
| Max. PV Input Power (W) | 2800 |
| Max. Input Voltage per Input (V) | 60 |
| Operating Voltage Range per Input (V) | 16 ~ 60 |
| Quantity of PV Module | 4 |
| Battery (DC) | |
| Battery Type | LiFePO₄ |
| Battery Capacity (kWh) | 4 |
| Max. System Capacity (kWh) | 20 |
| Nominal Voltage (V) | 51.2 |
| Life Cycle | 10,000⁽¹⁾ |
| AC Port (On-grid) | |
| Max. AC Output Power (W) | 800⁽²⁾ / 2500⁽³⁾ |
| Max. AC Input Power (W) | 2500⁽⁴⁾ |
| Nominal AC Voltage (V) | 220 / 230 / 240 |
| Nominal AC Frequency (Hz) | 50 / 60 |
| AC Port (Off-grid) | |
| Max. AC Output Power (W) | 2500⁽⁵⁾ |
| Nominal AC Voltage (V) | 220 / 230 / 240 |
| Nominal AC Frequency (Hz) | 50 / 60 |
| Switch Time (ms) | ≤10 |
| General Data | |
| Dimensions (W × H × D mm) | 583 × 410 × 395 |
| Weight (kg) | 48 |
| Communication Mode | WiFi (Bluetooth) + RS485 |
| Protection Degree (IP Rating) | IP65 |
| Cooling Method | Natural Convection |
| Operating Temperature Range | -20 ~ 55℃ |
| Relative Humidity | 0 ~ 95%, Non condensing |
| Max. Operating Altitude (m) | 2000 |
| Protection Level | I |
| Overvoltage Category | II (DC); III(AC) |
| Model | TSOL-B2000Lite | TSOL-B4000Lite |
| Battery Specifications | ||
| Battery Type | LiFePO₄ | LiFePO₄ |
| Battery Capacity (kWh) | 2 | 4 |
| Nominal Voltage (V) | 51.2 | 51.2 |
| Life Cycle | 10,000⁽¹⁾ | 10,000⁽¹⁾ |
| General Data | ||
| Dimensions (W×H×D mm) | 583 × 333 × 375 | 583 × 333 × 375 |
| Weight (kg) | 26 | 35 |
| Protection Degree (IP Rating) | IP65 | IP65 |
| Cooling Method | Natural Convection Cooling | Natural Convection Cooling |
| Operating Temperature Range | -20 ~ 55℃ | -20 ~ 55℃ |
| Relative Humidity | 0 ~ 95%, Non condensing | 0 ~ 95%, Non condensing |
| Max. Operating Altitude (m) | 2000 | 2000 |
This is a bush made up of 2 concentric tubes between which of elastomer is bonded. Under the effect of external forces or torques, the relative movement of the tubes will cause an elastic deformation of the elastomer. By consulting the service conditions, a bush should be chosen which will remain within its elastic operational limits..
Product Video
We value your privacy
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
Customise Consent Preferences
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.